Home Page - Products - Cosmetics & Biopharma Division - Labodorf - Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin

Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Labodorf SWL-15 Trans Epidermal Water Loss Analyzer Japan Origin
Description

VAPOSCAN AS-VT100 portable TEWL analyzer adopts closed chamber technology, anti-airflow interference, multi-size optional probes, RS232 data output. Comply with EEMCO & FDA standards for cosmetic efficacy test, topical drug R&D and dermatology research.

Application

1. Tests and studies on the efficacy claims of cosmetic manufacturers, such as anti-acne, repair, soothing and moisturizing. 2. Research and testing related to skin disease models (atopic dermatitis, psoriasis, eczema, photoaging , etc.) of experimental animal(e.g. mice) in medicine research centers. 3. Basic scientific research related to skin physiological barrier characterization in dermatology and aesthetic medicine research in medical schools. 4. The skin barrier integrity testing for in vitro permeation test in the research and development of topical drug products, transdermal drug delivery and other preparations in the pharmaceutical industry.

Product Description

image.pngimage.png

In order to maintain the skin in good condition,  try to avoid the factors that lead to the increase of  TEWL, such as direct sunlight, bad weather and  temperature, clothes that are easy to cause itching and so on. In addition, you can apply sunscreen, and use a gentle and less abrasive body wash when  taking a shower. Of course, using moisturizing cream can also help to keep your skin in a good moisture   Human skin normally loses a small amount of water. Under certain conditions, such as  acne, skin inflammation, dehydration etc., transepidermal water loss is much higher than normal. The TEWL value (Trans Epidermal Water Loss) is the main parameter for non-invasive and  objective assessing of the skin barrier function, and TEWL measurement is an important method for the study ofskin irritation caused by various physical and chemical influences. Typical  applications are the evaluation of the efficacy test of various cosmetic products, such as:  moisturizing, anti-acne,repair, snoothing, exfoliation etc ., the development of formulations for  skin care products, R&D of topical drugs for skin diseases, and so on.  state.The accuracy of TEWL measurement is affected by environmental factors, such as temperature and humidity, airflow and internal factors of human body. Therefore, the measurement of TEWL must be carried out under standardized conditions.

VAPOSCAN AS-VT100 is a professional closed-chamber portable TEWL analyzer developed for objective, non-invasive evaluation of human & animal skin barrier function, fully compliant with EEMCO, FDA and OECD skin testing standards.Transepidermal Water Loss (TEWL) is the core quantitative indicator of skin barrier integrity: damaged stratum corneum caused by inflammation, dryness, acne or irritation will sharply raise TEWL value. This tester is the standard lab equipment to verify cosmetic moisturizing, soothing, anti-irritation, barrier repair efficacy, as well as evaluate skin penetration safety of topical pharmaceuticals.Different from open-type TEWL devices vulnerable to ambient wind, AS-VT100 adopts fully enclosed detection chamber. When the probe contacts skin surface, the internal sensor records real-time absolute humidity change within 10 seconds, automatically calculates standardized TEWL value (g/m²/h). Built-in high-speed CPU eliminates manual operation errors, automatically judges stable measurement endpoint to guarantee repeatable experimental data.

The instrument supports interchangeable multi-size probes to cover all test sites from large forearm skin to tiny lip, periocular, scalp and mouse skin. Dual power design enables flexible use in constant-temperature-humidity cosmetic labs, hospital dermatology departments, university pharmacology labs and toxicology testing institutions. All test data can be transmitted to PC via RS232 serial port; matched DAQ software supports batch data sorting, curve plotting and formal experiment report export.Widely recognized in cosmetic claim substantiation, transdermal drug IVPT testing, chronic skin disease model research and EU REACH raw material skin irritation risk assessment, AS-VT100 provides traceable, comparable quantitative data for global skin pharmacology & cosmetic efficacy laboratories.


  • Closed Chamber Measuring Technology: Fully shield external airflow turbulence, stable TEWL data without environment interference, meets EEMCO official test guidelines.
  • Ultra-fast Detection: Single measurement completes within 5–14 seconds, automatic identification of start & stop measurement timing by built-in high-performance CPU.
  • Wide Measurement Range & High Precision: TEWL range –100 ~ 300 g/m²/h, 0.1 g/m²/h ultra-fine resolution, capture both mild & severe skin water loss accurately.
  • Replaceable Multi-aperture Probes: Standard 12mm probe, optional 10/8/6/4mm probes, adapt to cheek, eye area, lip, scalp, nail, forearm and tiny animal skin sites.
  • Dual Power Supply Mode: Support 9V battery & AC adapter, lightweight 200g body for field portable testing or fixed lab workstation use.
  • Complete Real-time Data Monitoring: Simultaneously display TEWL value, temperature, humidity & SD variation; RS232 data export + optional DAQ analysis software for lab report archiving.
  • Non-invasive Safe Test: Gentle probe contact, no skin damage, suitable for human volunteer clinical trials & animal dermatitis model research.


Message Us
Product *
Name *
Phone *
Email *
Country
Message
Enter product name
Enter your name
Enter your email
Your phone number
Enter company name
Enter country name
Your message
Product Name cannot be empty!
Name cannot be empty!
Please enter a valid phone number!
Please enter a valid E-mail!
Commpany Name cannot be empty!
Country Name cannot be empty!
The message content cannot be empty!
Submitted Successfully
Submission Failed
Recommended Products

Copyright ©Labcan Scientific 2026All Rights Reserved PoweredPrivacy PolicyTerms Of Servicesitemap.xml

+86 18016316889

Scan To Add WeChat